Epic Code LAB2111401 Leukocyte Adhesion Deficiency by Flow Cytometry
Test Name Alias
Leukocyte Adhesion Deficiency by Flow Cytometry | LAD | LAD1 | 911
Interface Order Alias
11415
Clinical Information
Leukocyte Adhesion Deficiency is an autosomal recessive immunodeficiency disorder characterized by leukocyte dysfunction which results in recurrent infections. The laboratory test for LAD involves the flow cytometric measurement of CD18, CD11b, and CD15 on neutrophils. LAD Type 1 is characterized by absent or reduced expression of CD11b and CD18 on neutrophils. LAD Type 2 is less common and exhibits absent or decreased expression of CD15 on neutrophils. Type 3 LAD is not evaluated by this assay.
Collection Instructions
Collect only Monday through Friday.
Specimen Type: Whole Blood
Container/Tube: Lavender top (EDTA) preferred, Green top (Sodium Heparin) acceptable
- Volume: 2.0 mL
- Minimum Volume: 1.0 mL
- Pediatric Volume: 0.5 mL
- Capillary collect ok? No
- Microtainer acceptable? Yes
Processing Instructions (Laboratory, Outpatient or Off-site collection)
- Processed Specimen: Whole Blood
- Centrifuge/Spin: No
- Aliquot: No
- Transport Temperature: Ambient
Specimen Stability
Ambient: 48 hours
Refrigerated: Unacceptable
Frozen: Unacceptable
Test Frequency
Monday – Friday, usual TAT 2 days.
- Test not available on weekends or holidays.
Reference Range
See report: See patient chart report for interpretation
Performing Department
FLOW CYTOMETRY
Performing Department Laboratory Location
Spectrum Health Advanced Technology Laboratory (ATL), Grand Rapids, MI
Methodology
Flow Cytometry
CPT
88184, 88185 x ea
First cell surface marker will be billed with CPT code 88184. Each additional surface marker will be billed with CPT code 88185. The quantity of surface markers varies with each patient case and will be billed accordingly based on quantity performed. Corresponding professional fees will also apply.
CDM Code
4028304, 4028305
Epic Test ID
1230100883
Beaker LOINC
LOINC Not available
Reviewed Date
7/31/2021
Beaker Names
Beaker Procedure Name: LEUKOCYTE ADHESION
DEFICIENCY BY FLOW CYTOMETRY
Beaker Display Name: Leukocyte Adhesion Deficiency
by Flow Cytometry
BEAKER TEST NAME: LEUKOCYTE ADHESION DEFICIENCY BY
FLOW CYTOMETRY
BEAKER TEST REPORT NAME: Leukocyte Adhesion
Deficiency by Flow Cytometry
Beaker Synonyms
LAD
Beaker Collection and Specimen Handling
BEAKER COLLECTION: AP Ambient LOOK+LOOK
Beaker Location, Container and Temperature
LC FLOW CYTOMETRY: 4 ML GREEN NA HEPARIN TUBE (Preferred)-No Temperature