Sign in →

Test Code LAB2111417 Paroxysmal Nocturnal Hemoglobinuria (PNH) by Flow Cytometry

Test Name Alias

PNH |CD59 | P1 linked antigen | P1 Anchor | GPI linked antigen | Flaer | High Sensitivity PNH | 915

Specimen Requirements

Submit only one of the following specimens:


Preferred
Specimen Type: Whole blood
Container/Tube: 2 Lavender top (EDTA)
Volume: 6.0 mL
Minimum volume: 2.0 mL

Pediatric volume: 1.0 mL


Acceptable
Specimen Type: Whole blood
Container/Tube: Green top (Sodium heparin)
Volume: 6.0 mL
Minimum volume: 2.0 mL

Pediatric volume: 1.0 mL

Specimen Transport Temperature

Ambient

Specimen Stability

Ambient: 48 hours

Laboratory Retention:

Test Frequency

Monday – Friday 8:00am – 4:00pm, usual TAT 3 days.

Reference Range

An interpretative report will be provided.

Performing Department

Flow Cytometry

Performing Department Laboratory Location

Spectrum Health Regional Laboratory (SHRL) – Advanced Technology Laboratory (ATL), Grand Rapids, MI

Methodology

Flow Cytometry

CPT

88184, 88185 x 6, 88187

CDM Code

4028304, 4028305

Interface Order Alias

11431

Reviewed Date

4/11/2018