Sign in →

Epic Code LAB3274 Eosinophilia (EOS) Probe Panel by FISH

Test Name Alias

EOS by FISH | 9224

Interface Order Alias

11605

Clinical Information

This probe panel detects specific numerical and structural chromosome abnormalities commonly associated with eosinophilia.

 

Routine chromosome analysis is performed on all bone marrow specimens and is recomended on all diagnostic samples specimens to exclude abnormalities not identified by the specified FISH probe(s).

Collection Instructions

Multiple specimen collection types. Submit only one:

 

Specimen Collection: Bone Marrow

Container(s): Green Top (Sodium Heparin)

Preferred volume to collect: 5.0 mL

Minimum volume to collect: 1.0 mL

Neonate volume to collect: 1.0 mL

Collection Instructions:

  • Collect bone marrow and transfer marrow from syringe to plain green top sodium heparin tube. 

 

Specimen Collection: Peripheral blood
Container/Tube: Green Top (Sodium Heparin)

Preferred volume to collect: 8.0 mL

Minimum volume to collect: 0.5 mL

Neonate volume to collect: 0.5 mL

Collection Instructions:

  • Peripheral blood may be substituted for Bone Marrow if circulating blasts are present 
  • Collect peripheral blood into a plain green top sodium heparin tube. 
  • Keep sample at room temperature and send to the Lab immediately. 

Processing Instructions (Laboratory, Outpatient or Off-site collection)

Spin: No

Aliquot: No

 

Transport Temperature: Ambient

 

If ambient temperature exceeds 80°F or is below 40°F, please send in an insulated container. All samples should be directed to the laboratory as soon as possible.

Specimen Stability

Ambient: 3 days (beyond 3 days, specimen viability will be detemined by Cytogenetics Lab)

Laboratory Retention: primary specimens 4 weeks; frozen pellets retained greater than 1 year

Test Frequency

Test Set Up: Monday – Friday 8:00 am – 5:00 pm, Saturday 8:00 am – 3:00 pm.

Technologist on call for Sunday set up.

Final report: 2-3 days.

Reference Range

An interpretative report will be provided.

Performing Department

CYTOGENETICS

Performing Department Laboratory Location

Spectrum Health Advanced Technology Laboratory (ATL), Grand Rapids, MI

Methodology

Performed by fluorescence in situ hybridization (FISH). This test was developed and its performance characteristics determined by Spectrum Health Cytogenetics Laboratory. It has not been cleared or approved by the US FDA. The FDA has determined that such clearance or approval is not necessary. This test is used for clinical purposes.

CPT

88275 x4, 88271 x9

CDM Code

4148275, 4148271

Epic Test ID

1230100648

LOINC

Specimen Type: 66746-9

Indication Provided: 42349-1

Result: in process

Interpretation: 59050-5

Comments: 69965-2

Beaker LOINC

LOINC Not available

Reviewed Date

10/22/2021

Beaker Names

Beaker Procedure Name: EOSINOPHILIA (EOS) PROBE PANEL BY FISH
Beaker Display Name: Eosinophilia (EOS) Probe Panel by FISH
BEAKER TEST NAME: EOSINOPHILIA (EOS) PROBE PANEL BY FISH
BEAKER TEST REPORT NAME: Eosinophilia (EOS) Probe Panel by FISH

Beaker Synonyms

EOS BY FISH

Beaker Collection and Specimen Handling

BEAKER COLLECTION: AP Ambient

Beaker Location, Container and Temperature

LC CYTOGENETICS: 6 ML NA HEPARIN TUBE A (Preferred)-Ambient
LC CYTOGENETICS: CYTOGENETICS MEDIA (Acceptable)-Ambient