Epic Code LAB71 IgG
Test Name Alias
Immunoglobulin G Blood Level | IgG Blood Level | 8212
Interface Order Alias
10177
Specimen Requirements
Submit only one of the following specimens:
Preferred
Specimen Type: Serum
Container/Tube: Gold Top (Serum Separator-SST Gel)
Volume: 5 mL
Minimum volume: 1.0 mL serum
Collection Instructions: Allow specimen to clot for 30 minutes and centrifuge within 2 hours
Acceptable
Specimen Type: Plasma
Container/Tube: Mint Green Top (Lithium Heparin Gel)
Volume: 4.5 mL
Minimum volume: 1.0 mL plasma
Collection Instructions: Centrifuge within 2 hours
Specimen Transport Temperature
Refrigerate
Specimen Stability
Ambient: 12 hours
Refrigerate: 72 hours
Frozen: aliquot serum for longer storage
Laboratory Retention: 72 hours
Test Frequency
Available daily, usual TAT 1 day.
Reference Range
Male/Female
0 up to 1 Month: 700 – 1400 mg/dL
1 Month up to 1 Year: 200 – 800 mg/dL
1 Year up to 4 Years: 400 – 1200 mg/dL
4 Years up to 10 Years: 600 – 1400 mg/dL
10 Years and up: 700 – 1500 mg/dL
Performing Department
Chemistry
Performing Department Laboratory Location
Corewell Health Reference Laboratory, Grand Rapids, MI
Methodology
Immunoturbidimetric
CPT
82784
CDM Code
3018278403
Epic Test ID
1230100831
LOINC
IgG: 2465-3
Mayo Access Code
SHO8212
Reviewed Date
3/7/2024