Sign in →

Epic Code LAB848 Streptococcus pneumoniae Antigen, Spinal Fluid

Important Note

Order as Reference Miscellaneous #LAB848; indicate complete test name when ordering.

Additional Codes

Mayo Code: SPNC

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Useful For

Rapid diagnosis of pneumococcal meningitis

Specimen Type

CSF
Laboratory Test Directory Note:

Lab Central Staff: All CSF specimens to Hematology first.


Additional Testing Requirements


According to the College of American Pathologists (CAP, IMM.41830), cerebrospinal fluid (CSF) samples collected to make an initial diagnosis and submitted for detection of Streptococcus pneumoniae antigen testing should also be submitted for routine bacterial culture. Mayo Clinic Laboratories recommends that CSF bacterial cultures be performed at the originating site.



Specimen Required


Container/Tube: Sterile vial

Specimen Volume: 1 mL

Collection Instructions: Submit specimen collected in vial 2, if possible. If not possible, note which vial from which the aliquot was obtained.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK

Day(s) Performed

Monday through Sunday

Reference Values

Negative

Reference values apply to all ages.

Clinical Information

Streptococcus pneumoniae is the most frequently encountered bacterial agent of community-acquired pneumonia, and can also be an agent of bacterial meningitis. Because of the significant morbidity and mortality associated with pneumococcal pneumonia, septicemia, and meningitis, it is important to have diagnostic test methods available that can provide a rapid diagnosis. In instances where empirical antibiotics are being considered prior to culture confirmation, antigen testing may be useful.

Cautions

A negative result does not exclude Streptococcus pneumoniae infection.

 

A diagnosis of Streptococcus pneumoniae infection must take into consideration all test results, culture results, and the clinical presentation of the patient.

 

Streptococcus pneumoniae vaccine may cause false-positive results, especially in patients who received the vaccine 5 or fewer days prior to specimen collection.

 

This assay has not been validated for use with body fluids other than urine or cerebrospinal fluid.

 

The performance of this assay has not been established for patients on antibiotic treatment for more than 24 hours.

Interpretation

A positive result supports a diagnosis of pneumococcal meningitis.

 

A negative result suggests that pneumococcal antigen is absent in the cerebrospinal fluid (CSF). However, infection due to Streptococcus pneumoniae cannot be ruled out since the antigen present in the specimen may be below the lower limit of detection of the test.

 

If pneumococcal meningitis is suspected, bacterial culture and Gram stain analysis on CSF should be performed.

Reporting Name

Streptococcus pneumoniae Ag, CSF

Method Name

Immunochromatographic Membrane Assay

Method Description

The BinaxNOW Streptococcus pneumoniae test is an immunochromatographic membrane assay used to detect pneumococcal-soluble antigen in cerebrospinal fluid. Rabbit anti-Streptococcus pneumoniae and anti-species antibodies are conjugated to visualizing particles that are dried onto an inert fibrous support. The resulting conjugate pad and the striped membrane are combined to construct the test strip.

 

To perform the test, a swab is dipped into the specimen, removed, and then inserted into the test device. Reagent A, a buffer solution, is added from a dropper bottle. The device is then closed, bringing the sample into contact with the test strip. Pneumococcal antigen present in the sample reacts to bind anti-Streptococcus pneumoniae conjugated antibody, forming the sample line. Immobilized control antibody captures anti-species conjugate forming the control line.

 

Test results are interpreted by the presence or absence of visually detectable pink-to-purple-colored lines. A positive test result, read in greater than or equal to 15 minutes depending on the concentration of antigen present in the sample, will include the detection of both a sample and control line. A negative test result, read in 15 minutes, will produce only a control line, indicating that Streptococcus pneumoniae antigen was not detected in the sample. Failure of the control line to appear, whether the sample line is present or not, indicates an invalid assay.(Package insert: BinaxNOW Streptococcus pneumoniae Test. Abbott; 01/15/2020)

CPT Code Information

87899

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SPNC Streptococcus pneumoniae Ag, CSF 20489-1

 

Result ID Test Result Name Result LOINC Value
31667 Streptococcus pneumoniae Ag, CSF 20489-1

Report Available

Same day/1 day

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

Clinical Reference

1. Plouffe JF, Moore SK, Davis R, Facklam RR: Serotypes of Streptococcus pneumoniae blood culture isolates from adults in Franklin County, Ohio. J Clin Microbiol. 1994 Jun;32(6):1606-1607

2. Johnston RB Jr: Pathogenesis of pneumonococcal pneumonia. Rev Infect Dis. 1991;13:509-517

3. Janoff EN, Musher DM: Streptococcus pneumoniae. In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases. 9th ed. Elsevier; 2020:2473-2491

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.